Release Notes: Intelli-Site 4.2.4.9
Created: 06-28-2023 10:17 AMLast Updated: 06-28-2023 10:49 AM

Operating Systems No Longer Supported

As of January 14, 2020, Microsoft Windows 7 and Windows Server 2008 R2 have reached end-of-life. Microsoft no longer supports these OSes. As such, OSSI no longer supports these operating systems. While our software will continue to install and upgrade on Windows 7 and Windows Server 2008 R2, we will not provide technical support for these systems for versions beyond Intelli-Site v4.0.45.12.  All customers and integrators are strongly encouraged to migrate to Windows 10 or Windows 2016.

Overview

This article contains the release notes for Intelli-Site v4.2.4.9 The following sections describe the release in detail and provide late-breaking or other information that supplements the main documentation.

Upgrade Requirements

Because the database has been redesigned, the installer will only upgrade version 4.0.45.12 or later. Minor modifications to the database had been implemented before version 4.0.45.12. Those modifications must be applied to the existing database for the software upgrade to properly upgrade the database.

The process is:

  1. Upgrade to version 4.0.45.12
  2. Open the Configuration Utility and start the Engine. The Engine performs the necessary modifications, not the installer. If there are multiple projects, each project must be started.
  3. Stop the Engine and close the Configuration Utility.
  4. Upgrade to the current version.
  5. Open the Configuration Utility and start the Engine. As stated in step 2, the Engine performs the necessary database upgrade not the installer. If there are multiple projects, each project must be started as well.

NEW FEATURES

The following software features were added

  • General
    • QR Code creation feature has been added for temporary card access.
  • Configuration Utility 
    • Newly restored/created project is now set as the current project.

The following Panels were added or upgraded:

  • Axis
    • Added the ability to import from DW/Wave.
    • Updated to the latest version of Axis Media Control.
  • Avigilon
    • Added option to switch to WAN mode.
  • Harding DXL
    • Created a new dedicated Harding DXL driver.
  • MAC
    • Associated points are now automatically renamed when a door is renamed.
  • Modbus
    • Update to the driver to allow coils to be set on and off.
  • PCSC IQ
    • Added Reader Name field to reader settings group.
    • Added a warning when the board model changes.
  • Vicon Valerus
    • Added the ability to change the streaming protocol.

RESOLVED ISSUES

The following issues affecting all products have been resolved:

  • Reports
    • Guard Tour Report was not sorted by start time.
    • Alarm Journal Report was not sorted by date/time correctly.
  • Configuration Utility
    • Note: Do not start the Client Manager unless you absolutely need it. Only start it when redundant Engines are required and licensed. The Client Manager counts as a client in the license.
      This isn't new. It just bears repeating.
  • Desktop Client
    • Only WAV files could be added to the sounds node.
    • Lost and Temp buttons should be disabled when adding a personnel record.
    • Counter value is not incremented when using Add/Rename from file option.
    • Deletion of a vehicle does not refresh the vehicle grid.
    • Import Cards ignores Activate_Date and Deactivate_date data included in import file.
  • Driver Specific
    • AXIS DW Wave: Deleting a camera node from quick config has no effect.
    • OPC: Clicking Apply clears the Nodes list box in quick config when adding nodes.
    • Senstar Drivers: The panel Status point is inverted.
    • PCSC IQ: Always send Logon in response to NAK not logged in message.
    • PCSC: Quick config requires you to apply before downloading.
    • PSCS IQ: Door Combo should show the door name, not the door lock name.
    • PCSC IQ: Panel drops offline during settings download if there is an empty Timezone.
    • Actall: Do not poll for alarms.
    • ASSA ABLOY DSR: Card_Valid field is inverted for card downloads.
  • General
    • Do not allow the same virtual point to be used as the Startup Point for two different computers.

The following issues specific to Intelli-Site Lite have been resolved:

  • N/A

Below are issues related to specific OEM versions:

  • N/A