Release Notes: Intelli-Site 4.2.3.7
Created: 01-04-2023 11:03 AMLast Updated: 06-28-2023 10:50 AM

Products to which this article applies

  • Intelli-Site
  • Intelli-Site Lite
  • LiNC-PLUS
  • LiNC-PLUS-Lite
  • MASC
  • MASC Lite

Operating Systems No Longer Supported

As of January 14, 2020, Microsoft Windows 7 and Windows Server 2008 R2 have reached end-of-life. Microsoft no longer supports these OSes. As such, OSSI no longer supports these operating systems. While our software will continue to install and upgrade on Windows 7 and Windows Server 2008 R2, we will not provide technical support for these systems for versions beyond Intelli-Site v4.0.45.12.  All customers and integrators are strongly encouraged to migrate to Windows 10 or Windows 2016.

Overview

This article contains the release notes for Intelli-Site v4.2.3.7 The following sections describe the release in detail and provide late-breaking or other information that supplements the main documentation.

Upgrade Requirements

Because the database has been redesigned, the installer will only upgrade version 4.0.45.12 or later. Minor modifications to the database had been implemented before version 4.0.45.12. Those modifications must be applied to the existing database for the software upgrade to properly upgrade the database.

The process is:

  1. Upgrade to version 4.0.45.12
  2. Open the Configuration Utility and start the Engine. The Engine performs the necessary modifications, not the installer. If there are multiple projects, each project must be started.
  3. Stop the Engine and close the Configuration Utility.
  4. Upgrade to the current version.
  5. Open the Configuration Utility and start the Engine. As stated in step 2, the Engine performs the necessary database upgrade not the installer. If there are multiple projects, each project must be started as well.

NEW FEATURES

The following software features were added

  • Reports
    • System time changes are now logged as an exception in the exceptions report.

The following Panels were added or upgraded:

  • Modbus
    • Update to use transaction IDs for better message tracking.

RESOLVED ISSUES

The following issues affecting all products have been resolved:

  • Reports
    • Custom History Report failing when secondary criteria was used
    • Reports with no criteria were failing to run
    • Timestamps were being incorrectly adjusted for timezone offset
  • Configuration Utility
    • Note: Do not start the Client Manager unless you absolutely need it. Only start it when redundant Engines are required and licensed. The Client Manager counts as a client in the license.
      This isn't new. It just bears repeating.
  • Desktop Client
    • Automatic renaming of associated points was not occuring when renaming points from design view
  • Driver Specific
    • Wisenet Wave Driver: Import of cameras from flat file was failing
    • Modbus Driver: Virtualizing the panel did not stop polling
    • Modbus Driver: System time changes caused the driver to stop polling properly
    • MAC Driver: User is notified when the ID received from a panel does not match the current panel type
    • MAC Driver: Request I/O status will now be sent periodically instead of a heartbeat to ensure point states are in sync
  • General
    • N/A

The following issues specific to Intelli-Site Lite have been resolved:

  • N/A

Below are issues related to specific OEM versions:

  • N/A